Function &Parameter:
• Supports Vector speed control (IMSVC) of asynchronous motor,Vector speed control (FMSVC) of synchronous motor
• Waterproof PG heads as wire holes,designed for harsh environments.
• VFD support V/F control or SVC open circuit vector control mode
• VFD Employs the latest generation IGBT power modules for quiet operation.
• The inverter features an integrated G/P design for easy customer applicability.
• VFD output frequency Max 3000Hz.
• VFD operates with a carrier frequency of 0.5 to 15KHz
• VFD Torque boost function of the electric motor by up to 30%
• VFD has a Standard built-in brake unit for 0.4KW- 30KW
• VFD Built-in PID, PLC, AVR, JOG, Timers, protections, EMC filter
• VFD has safety function EMS emergency machine stop
• VFD MODBUS support standard RS-485 physical communication interface
• VFD has 6 digital inputs, including 1 high-speed 20KHz pulse; 2 analog inputs are integrated input 0-10V and 4-20 mA input terminal
• VFD has 1 digital , 2 analog output support 0~20mA or 0~10V and 2 relay output terminal
Input Voltage (V) | 1PH AC220V ±10% 50~60Hz; 3PH AC220V ±10% 50~60Hz; 3PH AC380V ±15% 50~60Hz |
Output Voltage(V) | 3PH AC 0~input voltage; 3PH AC 0~input voltage; 3PH AC 0~input voltage |
Power Range (KVA) | 0.4KW~2.2KW; 0.4KW~75KW; 0.75KW~700KW |
Output Frequency Range | 0~500Hz |
Control Mode | V/F, SVC1, SVC2 |
Starting Torque | 0.5Hz/180%(SVC) |
Overload Capability | G type: 150% rated current 60s,180% rated current 3s P type: 120% rated current 60s,150% rated current 3s |
Communication port | RS-485:Modbus |
Protection level | IP65 |
Cooling method | Forced air cooling |
Fault Protection | Motor shortcircuit detection at poweron, input/output phase loss protection, over current protection, overvoltage protection, undervoltage protection, overheat protection and overload protection. |
The difference between a normal inverter and a fully sealed waterproof inverter in poor environments | ||
Comparative items | Normal inverter | Sealed waterproof inverter |
IP Class | Usually IP20 | IP65 |
Working life | Poor environment generally 2-3 months | 3-5 years in a poor environment is not a problem |
Installation method | Poor environment must be installed in a cabinet | Can be installed in the cabinet or exposed |
Working environment | Suitable for cleaner and drier applications | Suitable for poor environments |
Replacement frequency | Poor environment replaced more than three times a year | Poor environment replaced once every 3-5 years |
Product Name | PQ580-SF-FIG.1 | Product Name | PQ580-SF-FIG.2 | Product Name | PQ580-SF-FIG.3 | ||
Porduct Volotage | 0.75/1.5/2.2/3.0 | Porduct Volotage | 3.7/5.5 KW | Porduct Volotage | 7.5/11 KW | ||
Installation Dimension | 235*70mm | Installation Dimension | 235*70mm | Installation Dimension | 290*100mm | ||
Mounting hole diameter | Φ6 | Mounting hole diameter | Φ6 | Mounting hole diameter | Φ6 | ||
VFD Size | 145*170*250mm | VFD Size | 145*180*250mm | VFD Size | 175*180*305mm | ||
Product Name | PQ580-SF-FIG.4 | Product Name | PQ580-SF-FIG.5 | Product Name | PQ580-SF-FIG.6 | ||
Porduct Volotage | 15/18.5/22 KW | Porduct Volotage | 30 KW | Porduct Volotage | 45 KW | ||
Installation Dimension | 365*160mm | Installation Dimension | 407*180mm | Installation Dimension | 477*220mm | ||
Mounting hole diameter | Φ6 | Mounting hole diameter | Φ6 | Mounting hole diameter | Φ6 | ||
VFD Size | 235*195*380mm | VFD Size | 255*210*422mm | VFD Size | 295*215*492mm |
item | Specifications | |
Basic Functions | Motor Control Mode | V/F control |
Vector speed control (IMSVC) of asynchronous motor | ||
Vector speed control (FMSVC) of synchronous motor | ||
Maximum Frequency | Vector Control:0~300Hz V/F Control:0~3000Hz | |
Carrier Frequency | 0.5kHz~15kHz; the carrier frequency will be automatically adjusted according to the load characteristics. | |
Input Frequency Resolution | Digital Setting: 0.1Hz | |
Analog Setting: 0.01V corresponding maximum frequency ×0.025% | ||
Control Mode | V/F, SVC1, SVC2 | |
Startup Torque | 0.5Hz/180%(SVC) | |
Speed Range | 1:100(SVC); | |
Steady-state Speed Accuracy | ±0.5%(SVC) | |
Torque Control Accuracy | ±5%(SVC) | |
Overload Capability | G type: 150% rated current 60s,180% rated current 3s | |
P type: 120% rated current 60s,150% rated current 3s | ||
Torque Boost | Automatic Torque Boost, Manual Torque Boost 0.1%~30.0% | |
V/F Curve | Line Type,Multi-point Type, N-power V/F curve | |
Ramp mode | Straight-line ramp; S-curve ramp; | |
Four groups of acceleration/deceleration time with the range of 0.0 to 3200.0s. | ||
DC Brake | DC Brake Frequency:0.00Hz to maximum frequency. | |
Brake time: 0.0s to 36.0s | ||
Braking operation current value: 0.0%~100.0% | ||
Simple PLC multi-speed operation | Realize up to 16-speed operation through built-in PLC or control terminal. | |
Onboard PID | It realizes process-controlled closed loop control system easily. | |
Automatic Voltage Regulator (AVR) | Automatically regulates the output voltage to maintain a constant level regardless of grid voltage fluctuations. | |
Over-voltage/current Stall Control | The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to overvoltage/over current. | |
Fault current limiter | Protect the inverter by minimizing overcurrent conditions. | |
Torque limiting and control | It can limit the torque automatically and prevent frequent over current tripping during the running process. | |
Tailored options | Excellent performance | Implement motor control using advanced current vector control. |
Fault-tolerant: | Regenerative braking during a power sag enables the inverter to sustain operation. | |
Timing Control | Timing control function:set time range 0.0~3200.0Min | |
Bus Support | RS-485:Modbus | |
Running | Running Command Source | Operation panel/Control terminals/Serial communication port. You can perform switchover between these sources in various ways. |
Frequency Source | Digital setting, analog voltage setting, analog current setting, pulse setting and serial communication port setting. | |
Auxiliary frequency source | 10 kinds of auxiliary frequency sources. Flexible realization of auxiliary frequency fine-tuning and frequency synthesis. | |
Control Signal Input Terminal | 6 digital input terminals, one of which supports up to 20 kHz high-speed pulse input. | |
2 analog input terminals, one of which only supports 0-10 V voltage input and the other supports 0-10 V voltage input or 4-20 mA current input. | ||
Control Signal Output Terminal | 1 digital output terminal; 1 relay output terminal; | |
2 analog output terminal that supports 0-20 mA current output or 0-10 V voltage output. | ||
Control panel | LED DISPLAY | Five-digit numerical readout |
Key locking and function selection | It can lock the keys partially or completely and define the function range of some keys so as to prevent mis-function. | |
Protection Function | Motor short-circuit detection at power-on, input/output phase loss protection, over current protection, overvoltage protection, under voltage protection, overheat protection and overload protection. | |
Environment | Installation environment | Inside, avoid direct sunlight, salt, dust, corrosive or flammable gas, smoke, steam. |
Altitude | Below 1000 meters above sea level. (reduce the load level when used above 1000 meters above sea level) | |
Ambient Temperature | -10 ºC to +40 ºC (Derating use when under ambient temperature of 40 ºC to 50 ºC) | |
Humidity | Less than 95%RH, without condensing | |
Vibration | Less than 5.9m/s (0.6g) | |
Structure | Protection level | IP65 |
Cooling method | Forced air cooling | |
Installation method | Wall-mounted, floor-standing electric control cabinet. |
Metal processing ,digital machine tool, wire drawing bench and other mechanical equipment . paper making equipment ,chemistry industry ,medicine industry and textile industry ,all kinds of fans and pumping load .etc
Certification:
After Sales Service:
We provide reliable after-sales support to ensure your inverter operates efficiently. Our services include:
Technical Support: Available 24/7 for installation, troubleshooting, and operational guidance.
Warranty: Coverage for manufacturing defects and component failures.
Maintenance: Regular check-ups by certified technicians to keep your inverter in top condition.
Repairs: Quick and efficient repair services using genuine parts.
Training: User manuals and training sessions for proper operation and maintenance.
Spare Parts: Easy access to a wide range of spare parts for timely replacements.
Your satisfaction is our priority. Contact us for any assistance with your inverter.
OEM Services:
1. Logo
Please offer us your own high resolution logo in JPG format,there should be two colors at most in the logo and there should be no gradient effect in the logo.
2. Label
Please offer us your own model numbers.
3. Manual
Please offer us the finished manual file that can be printed directly.
Q1: What's The Advantages Of Your Products?
A1: We are a factory, so we have a number of production lines and first-class equipment and machines whichmeans we have hundreds of specifications. And also the company has the right to import and export, first-class quality, excellent service and praise, by domestic and foreign customers.